Austin › contractor

Faraday Electric

44 permits on record in Austin (2025-09-09 → 2026-10-20)

Rank in Austin

Electrical#41 of 333 (30 days, 5 permits)#77 of 1218 (12 months, 37)

Permits per month, last 12 months

11
12
02
04
05
06
07
08
09
10

Recent permits

IssuedTradeAddressWorkStatus
2026-10-20Electrical7316 HARMONY SHOALS BNDLevel 2 EV ChargerActive ↗
2026-10-20Electrical11800 QUINTANA CVLevel 2 EV ChargerActive ↗
2026-10-09Electrical11109 AMESITE TRLLevel 2 EV ChargerFinal ↗
2026-10-05Electrical10215 DIANELLA LNLevel 2 EV ChargerFinal ↗
2026-10-01Electrical8613 COBBLESTONELevel 2 EV ChargerFinal ↗
2026-09-22Electrical13203 BRIAR HOLLOW DRLevel 2 EV ChargerFinal ↗
2026-09-17Electrical8109 FRIDA BNDLevel 2 EV ChargerActive ↗
2026-09-15Electrical6907 DAUGHERTY STLevel 2 EV ChargerActive ↗
2026-09-07Electrical7001 WHEELER BRANCH TRLLevel 2 EV ChargerActive ↗
2026-09-07Electrical9812 IVALENES HOPE DRLevel 2 EV ChargerActive ↗
2026-08-24Electrical9915 DOUBLE EAGLE PASSLevel 2 EV Charger installationActive ↗
2026-08-24Electrical7208 TWILIGHT MESA DRLevel 2 EV ChargerActive ↗
2026-08-12Electrical3301 CANTWELL LNLevel 2 EV ChargerFinal ↗
2026-07-24Electrical2300 BOWMAN AVELevel 2 EV ChargerFinal ↗
2026-07-22Electrical5908 PASEO DEL TOROLevel 2 EV Charger powered by a 60amp Circuit Breaker. Run #6 THHN c.u. & #10 THHN c.u. ground through <45 feet New 3/4 EMT conduit and <5 fActive ↗
2026-07-22Electrical9600 PASATIEMPO DRLevel 2 EV Charger powered by a 50amp Circuit Breaker. Run #6 THHN c.u. & #10 THHN c.u. ground through <40 feet New 3/4 EMT conduit to powerActive ↗
2026-07-22Electrical12806 CEDAR STLevel 2 EV Charger powered by a 40amp Circuit Breaker. Run #8 THHN c.u. + #10 THHN c.u. ground <5ft 3/4 EMT conduit to power the Level 2 EV Final ↗
2026-07-22Electrical6704 BACK BAY LNLevel 2 EV Charger powered by a 60amp Circuit Breaker. Run #6 THHN c.u. + #10 THHN c.u. ground <5ft 3/4 EMT conduit to power the Level 2 EV Final ↗
2026-07-13Electrical8400 SKYTEX STLevel 2 EV Charger powered by a 60amp Circuit Breaker. Run #6 THHN c.u. & #10 THHN c.u. ground through <5 feet New 3/4 EMT conduit to power Final ↗
2026-06-12Electrical10913 CUSSETA LNLevel 2 EV Charger powered by a 60amp Circuit Breaker. Run #6 THHN c.u. & #10 THHN c.u. ground through <55 feet New 3/4 EMT conduit to powerFinal ↗
2026-06-05Electrical1509 BRAXTON VALLEY CVLevel 2 EV Charger powered by a 60amp Circuit Breaker. Run #6 THHN c.u. & #10 THHN c.u. ground through <5 feet New 34 EMT conduit to power tFinal ↗
2026-05-01Electrical1608 MORGAN LNLevel 2 EV Charger powered by a 60amp Circuit Breaker. Run #6 THHN c.u. & #10 THHN c.u. ground through <5 feet New 3 4 EMT conduit to power Final ↗
2026-04-29Electrical5011 BALCONES DR BLDG DLevel 2 EV Charger powered by a 60amp Circuit Breaker. Run #6 THHN c.u. & #10 THHN c.u. ground through <5 feet New 3/4 EMT conduit to power Final ↗
2026-04-17Electrical2010 GOODRICH AVE BLDG 6 UNIT BLevel 2 EV Charger powered by a 60amp Circuit Breaker. Run #6 THHN c.u. & #10 THHN c.u. ground through <5 feet New 3/4 EMT conduit to power Final ↗
2026-04-10Electrical311 E 54TH STNEMA 14-50 3R powered by a 50amp Circuit Breaker. Run #6 THHN c.u. & #10 THHN c.u. ground through <15 feet New 3/4 EMT conduit to power the Active ↗